Once the menu is open you can move between options with the arrow keys and select an option with the enter or space keys. Typeahead search is also available.
logo Go to Home Page

Industrial and Medical Gas Specifications (U.S.)

Argon

Purity 99.997%
Oxygen Less than 0.0005%
Dew Point
Liquid Argon: –90ºF or lower

Helium – Gaseous

Purity 99.995%
Oxygen Less than 0.0005%
Dew Point
–90ºF or lower

Helium – Liquid

Purity Not less than 99.999%
Oxygen Not more than 0.0001%
Dew Point
–105ºF or lower

Hydrogen – Gaseous

Purity 99.95%
Oxygen Less than 0.0005%
Dew Point
Gaseous Hydrogen: –90ºF or lower

Hydrogen – Liquid

Purity 99.999%
Oxygen Less than 0.0002%
Dew Point
Liquid Hydrogen:  –105ºF or lower

Medical Helium – Gaseous – meets USP

Purity Not less than 99.0%
Oxygen Not more than 1.0%
Carbon Monoxide
Not more than 0.001%
Odor
None

Medical Nitrogen – meets Nitrogen NF

Nitrogen and trace inerts 99.0%
Oxygen Not more than than 1.0%
Carbon Monoxide
Less than 0.001%
Odor
None

Medical Oxygen – meets Oxygen USP

Oxygen 99.0%
Odor
None

Nitrogen

Nitrogen and trace inerts 99.998%
Oxygen Less than 0.001%
Dew Point
Liquid Nitrogen: –90ºF or lower

Oxygen

Purity 99.5%
Inerts Less than 0.5%
Dew Point
Liquid Oxygen: –80ºF or lower